16/11/2011

VOLTAGES ENCORES UTILISES DANS LES ANNEES 1960...........68..

DANS CES ANNEES ON POUVAIT ENCORE TROUVER,SUIVANT LES ENDROITS,DES TENSIONS RESIDENTIELLES DE 110V,130V,220V,ET QUELQUE FOIS ,NOTEMMENT A ANGLEUR ,DU 190V,TENSION D'ATTENTE POUR LES ABONNES VOULANT LE 220V,MAIS DONT LE RESEAU PUBLIC ETAIT ENCORE DEPOURVU..

SUR LES RESEAUX TRADITIONNELS DE LA VILLE DE LIEGE,DE LA COMMUNE D'ANGLEUR,DE LA SOCIETE GAZ-ELECTRICITE HAINAUT-LIEGE,PUIS INTERCOM AU CENTRE D'ESNEUX ET SON QUARTIER DE HONY,ON TROUVAIT LES TENSIONS COMBINEES DE 110/190V.....CE QUI SIGNIFIE QUE TOUTES LES ALIMENTATIONS RESIDENTIELLES ETAIENT A 110V,TANDIS QUE LA FORCE MOTRICE ETAIT A 190V...

SI ON COMPARE AVEC LES RESEAUX PAR EXEMPLE DE L'ASSOCIATION LIEGEOISE D'ELECTRICITE A GRIVEGNEE,CHENEE ET EMBOURG,ON CONSTATE QUE CES DERNIERS ETAIENT AUX TENSIONS COMBINEES DE 127/220V...... ET DES LORS,LES ALIMENTATIONS RESIDENTIELLES ANCIENNES ETAIENT POUR LA PLUS PART EN 127V(130V...COMME ON DISAIENT ),ET LES NOUVELLES EN 220V......LES DEUX TENSIONS COHABITAIENT DONC POUR LE COURANT RESIDENTIEL...EN CE QUI CONCERNE LA FORCE MOTRICE,ELLE ETAIT DE 220V....


REVENONS A LIEGE,OU LE CHOIX FUT FAIT DES 1966,D'ABANDONNER LE 110/190V,POUR LE 220/380V....CE QUI  DOUBLAIT LA CAPACITE DES RESEAUX POUR UNE INTENSITE(AMPERAGE)EGALE... 

C'EST LA VILLE DE LIEGE QUI DEBUTA LA CONVERSION SUR LES CHAMPS DE FOIRE EN 1966...ET PAR LA SUITE DES 1967,LES ABONNES VIRENT LA PASSAGE AU 220V,QUARTIER PAR QUARTIER PAR  LES SOINS DE L'INTERMOSANE(GEREE PAR INTERCOM S.A.),A LAQUELLE LA VILLE S'ETAIT AFFILIEE...

PAR CONTRE A ANGLEUR,VU LA PRESQUE  TOTALITE DE LA COMMUNE EN RESEAUX AERIENS,ON A OPTE POUR UNE SOLUTION MOINS CHERE CONSISTANT AU REMPLACEMENT DES TRANSFORMATEURS 6300-110/190 V,PAR DES PLUS PUISSANTS MAIS POUVANT SORTIR EN RESEAU LE 127/220V......LE RESIDENTIEL DEVENAIT DONC PROVISOIREMENT DU 127V AU LIEU DE 110V ..CE QUI PERMETTAIT DE MODIFIER A LA DEMANDE DE L'ABONNE SA TENSION ,ET DE L'ALIMENTER EN 220V....(CE FUT COMMENCE EN 1967 PAR LA COMMUNE D'ANGLEUR,ET ACHEVE PAR L'ASSOCIATION LIEGEOISE D'ELECTRICITE A PARTIR DE 1969.).(SOCIETE INTERCOMMUNALE PURE A LAQUELLE LA COMMUNE VENAIT DE S'AFFILIER)
TOUTEFOIS L'A.L.E.,PLACA AUSSI DANS BEAUCOUP DE RUES,DES TORSADES LE LONG DES FACADES ET ETANT POUR BEAUCOUP D'ENTRE-ELLES ,ALIMENTEES EN 220/380V...LES ABONNES SE SITUANT COTE TORSADE,RECEVAIT PROGRESSIVEMENT DU 220V,MAIS ENTRE PHASE ET NEUTRE...LES CLIENTS QUI AVAIENT DES MOTEURS TRIPHASES,RESTAIENT ALIMENTES PAR L'ANCIEN RESEAU EN TRIPHASE 220V...

A ESNEUX, L'ASSOCIATION LIEGEOISE D'ELECTRICITE QUI A REPRIS L'EXPLOITATION EN 1965 LORS DE LA FIN DE CONTRAT "INTERCOM" AVEC LA COMMUNE....ENTREPRIS LA CONVERSION PROGRESSIVE EN REMPLACANT LE 110/190V PAR DU 127/220V.......  (cette formule étant une conversion douce,à la demande.....tandis que un passage directe au 220/380V,est un conversion en bloc et directe)

 

22:31 Écrit par ELECTRIFICATIONS EN PROVINCES DE LIEGE,NAMUR & LUXEMBOURG | Lien permanent | Commentaires (0) | Tags : voltages |  Facebook |